AP 22


Model Name |
AP 22 |
||
---|---|---|---|
Frequency (Hz) |
50 |
||
Fuel Type |
Diesel |
||
Engine Made and Model |
PERKINS - 404A-22G1 |
||
Alternator Made and Model |
Mecc Alte - ECP 28-M/4 C |
||
Control Panel Model |
DSE 6120 |
||
Canopy | AK 11 |
VOLTAGE | STANDBY RATING (ESP) | PRIME RATING (PRP) | Standby Amper | ||
---|---|---|---|---|---|
kVA | kW | kVA | kW | ||
400/231 | 22 | 17.6 | 20 | 16.0 | 31.76 |
PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
Engine |
PERKINS |
||
---|---|---|---|
Engine Model | 404A-22G1 | ||
NO. OF CYLINDERS AND BUILD | 4 cylinders - in line | ||
BORE AND STROKE | mm | 84 X 100 | |
TOTAL DISPLACEMENT | L | 2.216 | |
Aspiration | Naturally Aspirated | ||
COMPRESSION RATIO | 23.3:1 | ||
RATED SPEED (RPM) | d/dk | 1500 | |
OIL CAPACITY | L | 10.6 | |
Standby Power (kW/HP) | 20.6/27.61 | ||
Prime Power | 18.7/25,06 | ||
Block Heater QTY | |||
1 | |||
Block Heater Power (Watt) | |||
500 | |||
Fuel Type | |||
Diesel | |||
Injection Type and System | |||
Indirect | |||
Type of Fuel Pump | |||
Zexel Cassette type - In-Line | |||
Governor System | |||
Mechanic | |||
Operating Voltage (Vdc) | |||
12 Vdc | |||
Battery and Capacity (Qty/Ah) | |||
1x55 | |||
Charge Alternator (A) | |||
15 | |||
Cooling Method | |||
Water Cooled | |||
Coolant Capacity (engine only) (l) | |||
3.6 | |||
Total Coolant Capacity (l) | |||
7 | |||
Air Filter | |||
Dry Type | |||
Fuel Cons. Prime With %100 Load (lt/hr) | |||
5.3 | |||
Fuel Cons. Prime With %75 Load (lt/hr) | |||
4 | |||
Fuel Cons. Prime With %50 Load (lt/hr) | |||
2.9 |
Manufacturer | Mecc Alte | |
---|---|---|
Alternator Made and Model | ECP 28-M/4 C | |
Frequency (Hz) | Hz | 50 |
Power (kVA) | kVA | 20 |
DESIGN | 4 Pole, Brushless | |
VOLTAGE | V | 400 |
Phase | 3 | |
A.V.R. | DSR | |
Voltage Regulation | (+/-) | 1 |
Insulation System | H | |
Protection | IP23 | |
Rated Power Factor | 0.8 | |
WEIGHT COMP. GENERATOR (Kg) | 106 | |
COOLING AIR (m³/min) | m3 | 6.6 |
Open Type | DRY WEIGHT (kg.) (kg.) |
LENGTH (mm.) |
WIDTH (mm.) |
HEIGHT (mm.) |
TANK CAPACITY (lt.) (Lt.) |
---|---|---|---|---|---|
![]() |
500 | 1291 | 850 | 1092 | 38 |
CANOPY | DRY WEIGHT (kg.) (kg.) |
LENGTH (mm.) |
WIDTH (mm.) |
HEIGHT (mm.) |
TANK CAPACITY (lt.) (Lt.) |
AK 11![]() |
615 | 1851 | 906 | 1149 | 38 |
- Fuel-Water Seperator Filter
- Oil heater
- Anti-Condensation Heater
- Over sized alternator
- PMG excitation + AVR
- Main line circuit breaker
- Galvanized Coating
- ISO Container
- Marine Grade Paint
- Automatic synchronising and power control system (Multi gen-set Parallel)
- Parallel system with mains
- Transition synchronization with mains
- Alarm output relays
- Earth fault, single set
- Parallel system with mains
- Remote relay output
- Remote communication with modem
- Charge Ammeter
- Three or four pole contactor
- Three or four pole motor operated circuit breaker
- Main Fuel Tank
- Automatic or manual fuel filling system
- Electrical or manual oil drain pump
- Low and high fuel level alarm
- Inlet and outlet motorized louvers
- Inlet and outlet acoustic baffles
- Tool kit for maintenance
- 1500/3000 hours maintenance kit
- Supplied with oil and coolant (-30°C)
- Residential Silencer
- Silencer Spark Arrester
- Critical Silencer
- Catalytic Convertor

2. Close mains button
3. Main Status and instrumentation display
4. Alarm LED's
5. Close generator button
6. Status LED's
7. Operation selecting buttons

2. Close mains button
3. Main Status and instrumentation display
4. Alarm LED's
5. Close generator button
6. Status LED's
7. Operation selecting buttons
DSE model 6120, Auto Mains Failure control module, Static battery charger input 198-264 volt, output 27,6V 5A (24V) or
13,8 Volt 5A (12V), fuses for control circuits. This Control Module is suitable for a wide variety of single gen-set applications
Components installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion corrosion-resistant surface. Polyester composite powder topcoat forms a high gloss and extremely durable finish. Lockable and hinged panel door provides easy access to components.
Control panel is mounted on baseframe with steel stand. Located at the right side of the generator set (When you look at the Gen.Set. from Alternator side)
- The DSE 6120 module has been designed to monitor generator frequency, volt, current, engine oil pressure, coolant
temperature running hours and battery volts.
- Module monitors the mains supply and control the switch over to the generator when the mains power fails.
- The DSE6120 also indicates operational status and fault conditions, Automatically shutting down the Gen. Set and giving
true first up fault condition of Gen. Set failure.The LCD display indicates the fault.
ENGINE
●Engine speed.
●Oil pressure.
●Coolant temperature.
●Run time.
●Battery volts.
●Configurable timing.
GENERATOR
●Voltage (L-L, L-N).
●Current (L1-L2-L3).
●Frequency.
●Gen. Set ready.
●Gen. Set enabled.
MAINS
●Mains ready.
●Mains enabled.
- Flexible sensor can be controlled with temperature, pressure, percentage (warning/shutdown/electrical trip)
- Local setting parameters and monitoring from PC to control module with USB connection (max 6 mt).
- Electrical Safety / Electro Magenetic Compatibility (EMC)
- BS EN 60950 Electrical Safety
- BS EN 61000-6-2 EMC Generic Immunity Standard
- BS EN 61000-6-4 EMC Generic Emission Standard
- Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficiency.
- Battery charger models' output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and
27,6 V for 24 V . Input 198 - 264 volt AC.
- The charger is fitted with a protection diode across the output.
- Connect charge fail relay coil between positive output and CF output.
- They are equipped with RFI filter to reduce electrical noise radiated from the device.
- Galvanically isolated input and output typically 4kV for high reliability.

2 . Emergency stop push button
3 . Control panel is right side of the set.
4 . Corrosion.resistant locks and hinges
5 . Sump drains valves
6 . Sound proof foam metarial
7 . Base frame .tank
Enclosure, generator set, exhaust system and fuel tank are pre-ssembled, pre-integrated and shipped as one package
Body made from steel components treated with polyester powder coating
Fire retardant foam insulation
Easy access to all service points
Exhaust system inside canopy
Large doors on each side
Control panel viewing window in a lockable access door
Emergency stop push button mounted on enclosure exterior
Cooling fan and battery charging alternator fully guarded
Fuel fill and battery can only be reached via lockable access doors.
Lifting points on the top of canopy and base frame
Customer options available to meet your applications needs.
Aksa makes its generating sets' noise level tests in accordance with directive 2000/14/EC validation of the noise level test has been aproved by the notified body Szutest
CANOPY MODEL | AK 11 | |
---|---|---|
WIDTH | mm. | 906 |
LENGTH | mm. | 1851 |
HEIGHT | mm. | 1149 |
TANK CAPACITY (lt.) | Lt. | 38 |